Limited time75% off all plans
Get the app

Radiation Safety in Nuclear Medicine

Radiation Safety in Nuclear Medicine

Radiation Safety in Nuclear Medicine

On this page

Principles & ALARA - Dose Low, Safety High

  • Radiation Types:
    • $\alpha$: High LET, short range (internal hazard).
    • $\beta$: Med LET, med range (skin/internal).
    • $\gamma$/X-ray: Low LET, long range (external).
  • Key Units:
    • Activity: Becquerel (Bq), Curie (Ci). $1 \text{ Ci} = 3.7 \times 10^{10} \text{ Bq}$.
    • Absorbed Dose: Gray (Gy).
    • Equivalent Dose ($H_T$): Sievert (Sv) (Absorbed Dose $\times W_R$).
    • Effective Dose (E): Sievert (Sv) (sum of weighted $H_T$).
  • ALARA Principle: As Low As Reasonably Achievable.
    • šŸ“Œ TDS: Time (minimize ↓), Distance (maximize ↑, $I \propto 1/d^2$), Shielding (use).
  • Biological Effects:
    • Deterministic: Threshold dose. Severity $\propto$ dose (e.g., skin erythema >2 Gy).
    • Stochastic: No threshold. Probability $\propto$ dose (e.g., cancer).

⭐ Annual occupational effective dose limit (whole body): 20 mSv/year (avg. over 5 yrs), max 50 mSv in any year. ALARA Principle: Time, Distance, Shielding

Biological Effects & Dose Limits - Harm Alert, Limits Set

  • Biological Effects of Radiation:
    • Stochastic Effects: Probability increases with dose; NO threshold.
      • Examples: Carcinogenesis, genetic mutations.
    • Deterministic Effects (Non-Stochastic): Severity increases with dose; HAS a threshold dose.
      • Examples: Skin erythema, cataracts, sterility, organ dysfunction.
      • Cataract threshold: 0.5 Gy (acute exposure); 5 Gy (protracted exposure).
      • Temporary male sterility: ~0.15 Gy.
    • Tissue Radiosensitivity (Law of Bergonie & Tribondeau): Cells are more sensitive if they have:
      • High mitotic rate (actively dividing).
      • Long mitotic future.
      • Less differentiation (immature).
      • Most sensitive: Lymphoid organs, bone marrow, gonads.
  • Dose Limits (AERB Guidelines):
    • Occupational Worker:
      • Effective Dose: 20 mSv/year (averaged over 5 years); not to exceed 50 mSv in any single year.
      • Lens of Eye: 20 mSv/year.
      • Skin/Hands/Feet (Extremities): 500 mSv/year.
    • Public:
      • Effective Dose: 1 mSv/year.
    • Pregnant Worker (post-declaration):
      • Dose to Foetus: 1 mSv for the remainder of pregnancy.

⭐ Stochastic effects have no dose threshold and their probability is dose-dependent, whereas deterministic effects have a threshold dose below which they do not occur, and their severity increases with dose above this threshold.

Practical Protection Measures - Shield, Distance, Time Trio

šŸ“Œ TDS Principle: Key to ALARA (As Low As Reasonably Achievable).

  • Time: Minimize exposure duration.
    • Dose directly proportional to time.
    • Pre-plan; work efficiently.
  • Distance: Maximize distance from source.
    • Inverse Square Law: $I \propto 1/d^2$.
    • Use forceps, tongs, remote devices.
  • Shielding: Use appropriate barriers.
    • Gamma/X-rays: Lead (Pb) (aprons, syringe/vial shields, L-bench).
    • Beta (β⁻) particles: Low Z (Perspex/plastic) first (↓Bremsstrahlung), then Pb if needed.
    • HVL: Thickness for 50% attenuation.
    • TVL: Thickness for 90% attenuation (TVL ā‰ˆ 3.3 HVL).

⭐ For β⁻ emitters, use low Z (e.g., plastic) primary shielding to minimize Bremsstrahlung; high Z (e.g., lead) for secondary shielding if required.

Time, Distance, Shielding for Radiation Safety

Special Scenarios & AERB - Pregnancy, Spills, Rules

  • Pregnancy & Lactation:
    • Strict justification: Benefit vs. Risk. Aim for fetal dose < 1 mGy.
    • Breastfeeding interruption (consult specific guidelines):
      • Tc-99m (most common agents): 4 hrs to 24 hrs (confirm specific agent).
      • I-131 (therapy): Complete cessation.
      • I-123/I-131 (diagnostic): Days to weeks.
    • ⭐ > AERB: Therapeutic abortion not indicated for fetal radiation exposure < 100 mGy.
  • Radioactive Spills: (šŸ“Œ S.W.I.M. Protocol)
    • Stop spill, Warn others, Isolate area, Minimize exposure.
    • Notify Radiation Safety Officer (RSO). Decontaminate: Patient first, then area.
  • AERB Key Guidelines:
    • Occupational dose limits: Annual effective dose 20 mSv (averaged over 5 yrs); single year max 30 mSv. Fetus of worker: 1 mSv during declared pregnancy.
    • Public dose limit: 1 mSv/year.

High‑Yield Points - ⚔ Biggest Takeaways

  • ALARA principle (As Low As Reasonably Achievable) is the cornerstone of radiation protection.
  • The three cardinal principles are Time (minimize), Distance (maximize), and Shielding (use appropriate).
  • Distance is highly effective; radiation exposure decreases by the inverse square law.
  • Lead (Pb) aprons and thyroid shields are vital for personnel protection against gamma rays.
  • Personnel monitoring devices like TLD badges are mandatory for occupational exposure assessment.
  • The annual effective dose limit for radiation workers is 20 mSv, averaged over 5 years.
  • Pregnancy must be declared; the dose limit to the foetus is 1 mSv during the entire pregnancy period after declaration.

Continue reading on Oncourse

Sign up for free to access the full lesson, plus unlimited questions, flashcards, AI-powered notes, and more.

CONTINUE READING — FREE

or get the app

Rezzy — Oncourse's AI Study Mate

Have doubts about this lesson?

Ask Rezzy, your AI Study Mate, to explain anything you didn't understand

Enjoying this lesson?

Get full access to all lessons, practice questions, and more.

START FOR FREE