Gonioscopy in glaucomatocyclitic crisis shows a(n) _____-angle.
#2
PACG presents with symptoms such as _____, redness, photophobia, impaired vision, watering
#3
_____ glaucoma is characterized by sudden vision loss with halos around lights
#4
Gonioscopy should be done _____ doing IOP measurements while evaluating a patient with glaucoma
#5
Eyes with "pure" pupillary block are typically _____
#6
Ahmed glaucoma valve is a _____ based episcleral implant used as a glaucoma drainage device
#7
_____ implant is a silicon based, glaucoma drainage device (GDD)/seton/aqueous shunt, and carries the risk of postoperative hypotony due to excessive aqueous drainage (since it is valveless)
#8
_____ implant is a glaucoma drainage device
#9
_____ is the ideal method to visualize the fundus, especially for observing the optic-disc changes of glaucoma.
#10
Ex-Press™ glaucoma implant (Mini Shunt) is used in _____ to increase aqueous drainage
Hint: surgery
Primary Angle-Closure Glaucoma Indian Medical PG Flashcards - Medical Study Cards
Master Primary Angle-Closure Glaucoma with OnCourse flashcards. These spaced repetition flashcards are designed for medical students preparing for NEET PG, USMLE Step 1, USMLE Step 2, MBBS exams, and other medical licensing examinations.
Flashcard 1: Gonioscopy in glaucomatocyclitic crisis shows a(n) _____-angle.
Answer: open
Flashcard 2: PACG presents with symptoms such as _____, redness, photophobia, impaired vision, watering
Answer: pain
Flashcard 3: _____ glaucoma is characterized by sudden vision loss with halos around lights
Answer: Acute closed-angle
Flashcard 4: Gonioscopy should be done _____ doing IOP measurements while evaluating a patient with glaucoma
Answer: after
Flashcard 5: Eyes with "pure" pupillary block are typically _____
Answer: hypermetropic (myopic/hyperopic)
Flashcard 6: Ahmed glaucoma valve is a _____ based episcleral implant used as a glaucoma drainage device
Answer: silicone
Flashcard 7: _____ implant is a silicon based, glaucoma drainage device (GDD)/seton/aqueous shunt, and carries the risk of postoperative hypotony due to excessive aqueous drainage (since it is valveless)
Answer: Baerveldt
Flashcard 8: _____ implant is a glaucoma drainage device
Answer: Ex-Press
Flashcard 9: _____ is the ideal method to visualize the fundus, especially for observing the optic-disc changes of glaucoma.
Answer: Slit lamp biomicroscopy
Flashcard 10: Ex-Press™ glaucoma implant (Mini Shunt) is used in _____ to increase aqueous drainage