Acoustic reflex decay is a feature of _____ hearing loss
#2
If there is unilateral _____ hearing loss, the Weber test localizes to the affected ear
#3
What is the best audiometric test for diagnosing non-organic hearing loss?_____
#4
_____ frequencies affected first in conditions such as presbycusis, ototoxicity, noise induced hearing loss and intracranial schwannoma
#5
_____ is used to mask non-test ear while testing bone conduction.
#6
The following instrument is a _____
#7
_____ is the psycho acoustic unit of noise
#8
In noise induced hearing loss, there is a dip in the _____ conduction curve, called as Boiler's notch, maximally at 4000 Hz
#9
Negative Rinne for 256, 512 and 1024 Hz indicates a minimum AB gap of _____, 30, 45 dB, respectively.
#10
_____ test examines the effect of increased air pressure in ear canal on bone conduction
Otoacoustic Emissions Indian Medical PG Flashcards - Medical Study Cards
Master Otoacoustic Emissions with OnCourse flashcards. These spaced repetition flashcards are designed for medical students preparing for NEET PG, USMLE Step 1, USMLE Step 2, MBBS exams, and other medical licensing examinations.
Otoacoustic Emissions Flashcard Deck - 10 Cards
Flashcard 1: Acoustic reflex decay is a feature of _____ hearing loss
Answer: retrocochlear (cochlear/retrocochlear)
Flashcard 2: If there is unilateral _____ hearing loss, the Weber test localizes to the affected ear
Answer: conductive
Flashcard 3: What is the best audiometric test for diagnosing non-organic hearing loss?_____
Answer: BERA
Flashcard 4: _____ frequencies affected first in conditions such as presbycusis, ototoxicity, noise induced hearing loss and intracranial schwannoma
Answer: Higher
Flashcard 5: _____ is used to mask non-test ear while testing bone conduction.
Answer: Barany s noise box
Flashcard 6: The following instrument is a _____
Answer: tympanometer
Flashcard 7: _____ is the psycho acoustic unit of noise
Answer: Phon
Extra:
Flashcard 8: In noise induced hearing loss, there is a dip in the _____ conduction curve, called as Boiler's notch, maximally at 4000 Hz
Answer: bone and air
Flashcard 9: Negative Rinne for 256, 512 and 1024 Hz indicates a minimum AB gap of _____, 30, 45 dB, respectively.
Answer: 15
Flashcard 10: _____ test examines the effect of increased air pressure in ear canal on bone conduction
Answer: Gelle's
Keywords: Otoacoustic Emissions flashcards, medical flashcards, NEET PG preparation, USMLE Step 1 flashcards, Anki alternative, spaced repetition medical, OnCourse flashcards
Want unlimited flashcards?
Get full access to all flashcards, spaced repetition, and progress tracking.